Serial dilution calculator

This serial dilution calculator plans a dilution series. Enter the stock concentration, the dilution factor per step, the number of tubes and the volume you want in each, and it gives the volume to transfer, the diluent per tube and the concentration in every tube.

Your numbers are calculated in your browser and are not sent or stored.

Serial dilution calculatorOr describe it in Studio →

A factor of 10 is a tenfold (1:10) series, 2 a doubling series. The volume is what each tube holds after the transfer in.

Put 900 µL of diluent in each tube. Move 100 µL from the stock into tube 1, mix, then move the same volume from each tube into the next, with a fresh tip each time.

TubeDilutionConcentration
11:100.1 mg/mL
21:1000.01 mg/mL
31:1,0000.001 mg/mL
41:10,0001.00e-4 mg/mL
51:100,0001.00e-5 mg/mL
61:1,000,0001.00e-6 mg/mL

To report

10-fold serial dilution, 6 tubes: 100 µL into 900 µL diluent; 0.1 to 1.00e-6 mg/mL

Check your result: tube n should hold the stock divided by the factor n times: tube 6 of the opening tenfold series is 1 mg/mL ÷ 10⁶ = 1 × 10⁻⁶ mg/mL. Transfer plus diluent should equal the tube volume: 100 + 900 = 1,000 µL.
tubes at most
24
tubes at most
transfer for a tenfold step into 1,000 µL
100 µL
transfer for a tenfold step into 1,000 µL
factor per step from 1,000 to 1 in six tubes
3.16
factor per step from 1,000 to 1 in six tubes
mg/mL in tube 6 of the opening series
1 × 10⁻⁶
mg/mL in tube 6 of the opening series
  • Any factor: 2-fold, 10-fold, 1:3…
  • Up to 24 tubes
  • Transfer and diluent volumes
  • Concentration in every tube
  • Runs in your browser, free

01

How to do a serial dilution

  1. Label the tubes and add the diluent volume to each.
  2. Transfer the calculated volume from the stock into tube 1 and mix thoroughly.
  3. With a fresh tip, transfer the same volume from tube 1 into tube 2 and mix. Repeat down the row.
  4. The last tube holds extra volume (nothing is taken out of it); discard the transfer volume from it if every tube must be equal.
add solventstock: C₁, V₁diluted: C₂, V₂ = 3 × V₁
Dilution keeps the solute and adds volume. Both vessels hold the same 24 particles of solute. On the right the volume has been tripled, so each millilitre holds a third as many: the concentration falls by the dilution factor. That is what C₁V₁ = C₂V₂ says.

02

Serial dilution formulas

transfer volume = tube volume ÷ dilution factor
diluent volume = tube volume − transfer volume
concentration in tube n = stock ÷ factorⁿ

If you know the range you need instead of the factor, choose “Lowest concentration I need in the last tube”: the factor is then (stock ÷ lowest)^(1 ÷ number of tubes). Going from 1,000 to 1 in six tubes needs a factor of 3.16 per step.

“Tube volume” is the volume in a tube just after the transfer in. The dilution factor is total volume divided by the volume transferred: a 10-fold step is 1 part sample in 10 parts total.

03

Worked example: a tenfold series

The calculator opens with a 1 mg/mL stock, factor 10, six tubes of 1,000 µL: 900 µL of diluent in each tube and 100 µL transferred.

TubeDilutionConcentration
11:100.1 mg/mL
21:1000.01 mg/mL
31:1,0000.001 mg/mL
41:10,0001 × 10⁻⁴ mg/mL
51:100,0001 × 10⁻⁵ mg/mL
61:1,000,0001 × 10⁻⁶ mg/mL

04

Common series

SeriesFactorFor 200 µL per tubeTypical use
Doubling (2-fold)2100 µL into 100 µLMIC assays, antibody titres
3-fold366.7 µL into 133.3 µLDose–response curves
Tenfold1020 µL into 180 µLPlate counts, qPCR standards

05

Keeping the error small

  • Errors multiply down a series: a 3% pipetting error per step becomes about 20% after six steps. Mix each tube well and change tips every time.
  • Avoid transfer volumes below what your pipette handles accurately; raise the tube volume instead.
  • For a standard curve, fit the measured values with the linear regression calculator.

06

Common serial dilution mistakes

  • Adding the transfer to the full volume of diluent. 100 µL into 1,000 µL is an 11-fold step; after six tubes the dilution is 1,771,561, not 1,000,000, and the last tube is 44% weaker than labelled.
  • Letting small errors run. A 5% error at each step, all in the same direction, grows to 63% after ten tubes, because the errors multiply.
  • Forgetting the last tube. Nothing is taken out of it, so it holds 1,000 µL while the others hold 900 µL; remove 100 µL if every tube must match.

Trust

How this page is checked

  • The calculation runs on code with automated tests against worked reference values. Every number in the examples on this page was produced by that same code, not typed by hand.
  • The formulas and conventions used are stated on the page, so you can reproduce the result yourself or compare it with your own software.
  • Last reviewed by the Sciloom team, Zebra Nine Studio Inc. It is a tool for research and teaching, not a substitute for a statistician, a validated lab method or medical advice.

Cite this page

Sciloom. (2026). Serial dilution calculator. Zebra Nine Studio Inc. https://sciloom.si/serial-dilution-calculator

Read the full methodology · Who makes Sciloom

Frequently asked questions

How do I calculate a serial dilution?

Divide the volume you want in each tube by the dilution factor to get the transfer volume; the rest is diluent. Each tube’s concentration is the previous one divided by the factor.

What is a 1:10 serial dilution?

A series in which each tube is ten times more dilute than the one before: one part from the previous tube plus nine parts diluent, repeated.

How do I find the final dilution factor?

Multiply the factors of every step. Three tenfold steps give 10 × 10 × 10 = 1,000, written 1:1,000 or 10⁻³.

Why change the pipette tip at each step?

Liquid clinging to the tip carries extra sample forward, which makes later tubes more concentrated than calculated.

One dilution, not a series? The dilution calculator solves C1V1 = C2V2.